vio

vio

 英

  • 网络虚拟输入输出;失调电压;逻辑供电

例句

For instance, it is advisable, for the sake of redundancy and availability, to have at least two VIO Servers per managed frame.

例如为了冗余可用起见每个管理至少两个VIOServer可取

VIO SCSI disks configured in the global partition can be exported to a WPAR for use as a data disk or as the rootvg for the WPAR.

全局分区配置VIOSCSI磁盘可以导出WPAR作为WPAR数据磁盘rootvg

VIO technology can help you use resources more effectively, cut down on hardware costs, and consolidate servers in new and powerful ways.

VIO技术有助于有效地使用资源降低硬件成本新颖强大方式整合服务器

The resources that you assign to each VIO server should be as close to identical as possible and designed to maximize availability.

分配每个VIO服务器资源应该尽可能相同提供尽可能可用

This VIO server runs a special version of the AIX operating system, with an additional software package called IOS.

VIO服务器运行AIX操作系统特殊版本包含软件包IOS

The second virtual Ethernet adapter on each of the VIO Servers must be configured as a non-trunk adapter.

必须每个VIO服务器第二虚拟以太网适配器配置干线适配器

mkvdev: This command manages the virtual devices that you create and serve up to the VIO client LPARs.

mkvdev这个命令创建VIO客户机LPAR服务虚拟设备进行管理

Therefore, it is recommended to use at least two VIO Servers to host storage and network resources to the LPARs.

因此建议至少使用两个VIO服务器LPAR提供存储网络资源

For the VIO Server, you must allocate at least one storage controller and one Ethernet card.

对于VIOServer必须至少分配一个存储控制器一个以太网

In creating the VIO Servers, you assign disks to the server by assigning a storage controller to that server.

创建VIO服务器过程通过服务器分配存储控制器服务器分配磁盘

Do not mix a slower speed Ethernet adapter on one VIO server with a faster speed one on another.

不要一个VIO服务器设置以太网适配器另一个VIO服务器设置快速适配器

You can back up the VIO Server to a file, a tape device, CD, or DVD drive.

可以VIO服务器备份文件磁带设备CDDVD驱动器

You define virtual Ethernet and disk devices on the VIO Server and then make them available to the other LPARs on the system.

VIOServer定义虚拟以太网磁盘设备然后使它们系统其他LPAR可用

With the use of VIO LPARs, you could host 15 LPARs with a much smaller number of Ethernet and disk controllers.

通过使用VIOLPAR可以数量以太网磁盘控制器承载15LPAR

When configuring the profiles of the VIO Servers on the HMC, create two virtual Ethernet adapters on each server.

HMC配置VIO服务器概要每个服务器创建两个虚拟以太网适配器

You also learned how to improve recoverability by using NIM on an LPAR to house recovery images for your LPARs, VIO Servers, and HMCs.

了解如何LPAR使用NIMLPARVIO服务器HMC保存恢复镜像从而提高恢复

Set different trunk priority numbers between the two VIO servers.

两个VIO服务器设置不同中继优先

Building two VIO servers into the same System p hardware can provide redundancy in case one component fails.

一个Systemp硬件构建两个VIO服务器可以其中一个部件损坏提供冗余

These profiles will contain your VIO servers' configurations with virtual devices.

这些概要文件包含VIO服务器虚拟设备配置

Make sure each client adapter on the LPAR points to a different VIO Server.

确保LPAR每个客户端适配器指向不同VIO服务器

They permit physical adapters to be shared by one or more VIO client partitions.

它们物理适配器一个多个VIO客户端分区共享

VIO technologies consist of servers, software, and various commands.

VIO技术服务器软件各种命令组成

The screen shot of the second virtual Ethernet adapter for the VIO Servers should look the same.

VIO服务器第二虚拟以太网适配器屏幕截图看上去完全相同

When VIO servers are created, they are assigned both physical Ethernet adapters and virtual Ethernet adapters.

创建VIO服务器分配物理以太网适配器虚拟以太网适配器

In the HMC, make copies of the current VIO servers' profiles, and call them $SERVER. vio.

HMC复制当前VIO服务器概要文件它们命名$SERVER.vio。

Note: You created the VIO client LPAR as a blank slate so that you can define this easily.

注意作为slate创建VIO客户机LPAR这样可以方便地定义

The third area you need to plan is to have redundant VIO servers on the same physical pSeries or System P server.

需要规划第三方面一个物理pSeriesSystemp服务器设置冗余VIO服务器

Mapping disks to both VIO servers and creating network control channels gives VIO client LPARs two legs to stand on.

磁盘映射VIO服务器创建网络控制通道VIO客户机LPAR访问路径

Then, the VIO client LPARs are told the virtual Ethernet adapters and VLAN numbers they should access through an SEA mapping.

然后通过SEA映射告诉VIO客户机LPAR应该访问虚拟以太网适配器VLAN编号

If you need to make this SEA available from the VIO Server, use the mktcpip command to set an IP address on it.

如果需要VIO服务器使用这个SEA那么使用mktcpip命令上面设置IP地址

Just make sure the Virtual LAN ID field has the same value as the trunk adapters in the VIO Server configurations (see Figure 5).

只需确保VirtualLANID字段VIO服务器配置干线适配器具有相同请参见5)。

cfgdev: This command is the equivalent of the cfgmgr command and detects new physical and logical devices added to the VIO server.

cfgdev这个命令相当于cfgmgr命令探测VIO服务器添加物理逻辑设备

Shut down your VIO servers, and activate them from these profiles, or dynamically add the same resources to the LPARs.

关闭VIO服务器这些概要文件启动它们或者动态地LPAR添加相同资源

Benefits: This method is an extremely elegant way to manage VIO disk resources and simplifies the process of mapping disks.

好处这种方法可以非常优雅管理VIO磁盘资源简化磁盘映射过程

And, an errant rmlv command can completely knock a VIO client LPAR off of the wire.

另外错误rmlv命令可能导致VIO客户机LPAR完全离线

It also makes it possible to perform IOS upgrades on the VIO servers dynamically without affecting the VIO client LPARs.

允许VIO服务器动态地执行IOS升级不会影响VIO客户机LPAR

The SAS tape adapter is owned by the VIO server partition, similar to NPIV.

SAS磁带适配器VIO服务器分区所有类似NPIV

Insufficient resources in the VIO server can bottleneck the whole system.

VIOS服务器资源不足可能造成整个系统瓶颈

Make sure you make the virtual disk devices of the LPAR the same size on each of the VIO Servers.

确保每个VIO服务器LPAR虚拟磁盘设备容量相等

When you need to build an LPAR or install AIX software quickly, making an ISO image available to the VIO client takes seconds.

需要快速构建LPAR安装AIX软件可以VIO客户机访问ISO映像

热门查询